Today’s tasks
Tomorrow’s preview
Rooms & chambers
Setpoints are development targets; pinning RH targets appear on each tile. Mixed-age cohorts share the development target (pin misting is not separately simulated). Duties use monthly normals and continuous conditioning, including empty-room standby. Add incubation, sterilizer, lab and pack modules using Site growth. The break-even start sizes every module together.
Production desk
AUTO looks ahead to first harvest and subtracts already committed flushes. MANUAL starts the weekly quantity as capacity allows. Knobs change future turns; restarting restores the selected start. Break-even starts use a constant MANUAL weekly plan with seasonal channel caps. A chamber change waits for its assigned cohorts to finish.
Recovery is a performance requirement, not selected equipment: HRV defaults to the required 70% sensible recovery; ERV adds an estimated 60% latent effectiveness. Humidifier methods are placeholders until equipment is chosen: evaporative defaults to 0.005 fan kWh/lb plus 1,061 Btu/lb removed from room sensible heat. Make your own spawn or buy it in Settings.
Supply & demand · 52 weeks
Site growth
A proposed container farm. Add a room where there is space and a clear walking route.
C1 lab + incubation · C2 first fruiting chamber · C3 pack · C4 greens. Green dashed boxes are available comb slots; gray footprints and the track remain reserved.
Raw materials in · mushrooms out
Materials are reserved when a cohort starts. Chamber accounts include their assigned cohorts’ lab/incubation work and a block-day share of fixed-room energy. Stock follows its original chamber through sale or fallback.
By species
By chamber
Cost per harvested pound
Materials + electricity + labour + annualized capital (including fit-out and shared modules in scalable mode). Waste write-off is reclassified material cost, never added twice. Period costs include work in progress and standby; revenue includes fresh sales and drying recovery. No harvested pounds means no ratio.
Break-even volume · steady year
Channel commitments and prices
Monthly electricity by duty
Heating/cooling COP, humidifier and dehumidifier conversions are equipment placeholders. Auxiliary electricity is shown separately. Steam supplies humidification heat directly. Evaporative humidification adds its latent duty to room heating or reduces sensible cooling; only its fan input appears under Humidify.
Settings
Labour multipliers are beside each species in Market. Own spawn adds its separately estimated handling time.
Where this number comes from
Published research, supplier specifications and labeled planning assumptions. Prices are a September 2026 snapshot; weather uses monthly climate normals.
Conflicts, missing costs & accounting boundaries
A planning simulation, including income and costs. Open the sources above for assumptions and limits.